High voltage air/oil fume purification power supply
Description
The AF05/OF05 is a series of highly compact and efficient, mains powered power supply. The primary application is for air or oil fume purification. However, it is also suitable for capacitor charging and other general purpose applications.
The AF05/OF05 Range has a precise, stable and adjustable output voltage and current controlled by adjusting the potentiometer at the front panel. It is safe and reliable, with a high tolerance to the noise generated by electrical discharges.
Input specifications
Input voltage | The input voltage range is 200V to 240V AC |
---|---|
Input current | Less than 5A |
Output specifications
Power range | 450W – 550W |
---|---|
Output voltage | 10kV, 15kV, 20kV adjustable |
Line regulation | Less than 1% |
Load regulation | Less than 1% |
Protection
Short circuit protection | In the event of an output short circuit, output current will remain at the set value. |
---|---|
Over-current protection | In the event of an output over-current, output current will remain at the set value. |
Spark protection | When the power supply experiences a spark on load, the output will be switched off momentarily. After which, it will be restored automatically. |
Controls
The power supply can be controlled by connecting to 9 way D type female connector at the rear.
Environmental details
Operating conditions – The following environmental limits should be observed when using the power supply.
Ambient temperature | -10°C to 50°C |
---|---|
Storage temperature | -20°C to 80°C |
Relative humidity | Less than 90% |
Mechanical details
Power range | 150W | 300W | 450W |
---|---|---|---|
Width (mm) | 150 | 150 | 150 |
Height (mm) | 95 | 95 | 95 |
Depth (mm) | 220 | 220 | 220 |
Weight (kg) | 1 | 1.5 | 1.6 |
Reliability and quality control
Each power supply has been tested with no load, a short circuit load and a sparking load. They have also been soak tested for no less than 48 hours at full load.
Safety
- This power supply contains hazardous voltages and stored energy. Contact with the output may result in fatal injury. It should only be used and maintained by trained personnel.
- The area where the power supply is to be used should be kept clean and dry
- Keep a safe distance from the output connector and any items connected to it
- Ensure that a secure connection is made between the Earth side of the load and the green and yellow Earth lead.